Correct answer: D — Have phases that cross the baseline more than four times, indicating increased fiber density or asynchronous firing within one motor unit
A phase crosses the baseline; a turn changes direction without crossing. Polyphasic MUPs (>4 phases) reflect desynchronized fiber firing and occur in both reinnervation and myopathy; serrated/complex MUPs have ≥5 turns and suggest early reinnervation or chronic denervation.
Teaching point: Long-duration, high-amplitude polyphasic MUPs suggest chronic reinnervation (neuropathic); short-duration, low-amplitude polyphasic MUPs with early recruitment suggest myopathy.
References
- Preston DC, Shapiro BE. Electromyography and Neuromuscular Disorders, 4th ed. Elsevier, 2021.